Compare physical interface and cabling types

Knowledge domainNetwork Fundamentals
Learning topic3 of 13
Questions8 questions
Study time35 min
AccessFree read-only learning
Question 1single_choice

Single-mode fiber, multimode fiber, copper

During a routine operations review, a NOC Engineer analyzes a high error rate on an interface connecting two switches in the 10.16.0.0/17 data center. The switches are 200 meters apart. The engineer issues a diagnostic command on the switch:

Switch# show interfaces status
Port      Name               Status       Vlan       Duplex  Speed Type
Gi1/0/1   Link-to-Dist       connected    trunk      a-full a-1000 1000BaseSX
Switch# show interfaces GigabitEthernet1/0/1
GigabitEthernet1/0/1 is up, line protocol is up (connected)
  ...
  12400 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort

The CRC counter alone does not identify the cause. During inspection of this connected optical link, which candidate installed fiber choice would conflict with the normal multimode-fiber specification of the shown SX optic and require verification?

Choose one answer.